A pack that fails inspection late in the process carries the cost of every operation already performed on it - cell sorting, connection, housing, testing. Scrapping it discards all of that. RMA’s battery pack rework stations give controlled access back into the pack at the cell, joint or module level: a failed connection can be re-welded, a damaged cell replaced, a module reopened and reclosed - on the same vision-verified, zero-gap process-control architecture used to build the pack in the first place, so the reworked joint meets the same quality gates as the original.
A wide range of materials, including challenging dissimilar-metal joints.
- STEEL
- STAINLESS STEEL
- COPPER (NICKEL-PLATED)
- COPPER ALLOYS
- NICKEL
- ALUMINUM
- LAYERED MATERIALS
Cell types
- Cylindrical - single-sided
- Cylindrical - double-sided
- Prismatic
- Pouch
- Blade
Reworked joint types
- Cell connectors
- Busbars
- Enclosures
- Measurement tabs
- Fuses

Where pack rework fits.
Rework is configured around the failure mode and the pack architecture it needs to recover - closest to the processes where thermal control and joint access matter most.
§ 07 - PROCESS CONTROL
We control the process at every stage - per joint, not per batch.
VISION
Joint detection
Vision detects the position of every joint before welding, so each weld lands exactly where it should.
PRESS
Gap elimination
Mechanical pressing brings the parts into contact and eliminates the gap at every joint.
HEIGHT
Tolerance compensation
Height measurement compensates assembly tolerances across the whole module.
FOCAL
Focus per joint
Focal position is corrected for every joint, not set once per batch.
WELD
Controlled energy input
Beam shaping and power profile selected for the material pair - copper, aluminum, nickel, layered.
MONITOR
Online monitoring & trace
Process signals captured per weld. Every joint is logged - documented, reproducible, audit-ready.
QUALITY GATES
Quality is verified before, during and after every weld.

The machine refuses to weld a bad joint.
Vision recognition locates each joint, the clamping unit eliminates the gap, connection height is measured and focal position adjusted. If preconditions are not met, the weld does not start.

Every weld monitored in real time.
Controlled energy input and online process monitoring track the weld as it happens - deviations are flagged at the joint, not discovered in the field.

Documented proof, not assumptions.
Weld data recorded per joint and per pack, transferable to your database. Processes are validated at the Laser Application Center with metallographic examinations, tensile testing and macroscopic analysis.
From a failed joint to a validated rework procedure.
Failure analysis at the LAC - the failed joint or cell root-caused on your actual pack before a rework procedure is defined.
Rework process engineering - access strategy, re-weld or replacement parameters and a verification plan matched to the failure mode.
Build & integration - the station built and validated against your pack geometry.
Support - spare parts, remote diagnostics and process optimization across the station's life.
Don't scrap the pack - rework it.
Rework is configured around your failure mode and pack architecture. Send us the joint or cell that failed - we'll validate a rework procedure at the LAC before it reaches your line.