KNOWLEDGE · APPLICATION NOTE

Laser Focal Point Measurement for Battery Welding - Methods Compared

On 250-300 µm copper and aluminum, the focal position decides whether a battery weld is stable. Here is why the focal point of a single-mode laser is so hard to locate, how much accuracy the process really needs - and how the three practical measurement methods compare on precision, objectivity and cost.

Based on the article by Rajmund Pobereżny, Project Manager - RMA. Full version as a PDF below.

Focus is a process parameter, not a machine setting

Battery modules join materials that do not like each other: copper, aluminum and stainless steel, often in thicknesses of 250-300 µm. Such joints are welded with lasers of very high beam quality - single-mode and dual-beam (core + ring) sources - whose focal spot is only 45-60 µm in diameter. With a spot that small, the energy density on the part depends directly on where the beam waist sits relative to the joint.

That is why, in battery laser welding, focal position belongs on the same list as laser power, welding speed and weld geometry. Get it wrong and the weld changes - even if every other parameter is set perfectly.

Two distances, one tolerance chain

“Focus” on a production machine is really two measurements:

  1. Head to workpiece - a physical distance between two objects. It can be measured with ordinary, sufficiently accurate tools.
  2. Head to the focal point - the distance at which the beam diameter is smallest. This is the hard one, because there is nothing physical to touch.

Only when both are known does the beam waist land on the joint. Here is how each key parameter is typically verified in a battery welding cell:

ParameterHow it is verifiedDifficulty
Laser powerIndustrial power meter (pulse heat → power), before process setup and periodically - also reveals contamination in the optical pathLow
Speed and weld geometry2D / 2.5D / 3D galvo scanners reproduce velocity and geometry precisely; no extra monitoring neededLow
Head-to-workpiece distancePrecise distance measurement between the head and the partMedium
Head-to-focal-point distanceRequires locating the minimum beam diameter along the axis - see methods belowHigh

Why the focal point is so hard to locate

  • The beam is not an object. Rulers, calipers and micrometers are useless.
  • It is invisible. Most industrial lasers operate at about 1,060 nm - infrared.
  • It is tiny. A 45-60 µm spot leaves very little to see on a plate.
  • It has no sharp minimum. A Gaussian beam cannot be focused to a point; it forms a beam waist, and over the Rayleigh length the diameter changes only slowly. Two positions close to focus look practically the same.
Gaussian laser beam waist: waist radius w0, Rayleigh length zR and divergence angle
Near the focus, a Gaussian beam forms a waist rather than a point - the diameter changes slowly over the Rayleigh length zR. Diagram: DrBob, Rodolfo Hermans / Wikimedia Commons (GaussianBeamWaist.svg), CC BY-SA 3.0.

How much accuracy does the process need?

The answer depends on the material thickness and the optics:

ProcessTypical focal spotRequired focal-position accuracy
Steel, thicknesses in millimeters, lower beam qualityup to 500-700 µm0.5-1 mm
Thin battery joints (≤ 300 µm Cu, Al, steel), high power densityabout 50 µm50-100 µm

In practice: for busbar-to-cell and tab joints, choose a method with a precision of at least 100-150 µm. Methods worse than 500 µm are generally too coarse for 250-300 µm materials - the process may run, but it will not be repeatable. This matters most on copper, where the process window is narrow.

Three practical ways to find the focus

1. Pulse test on a plate

Short pulses are fired while the head-to-plate distance (typically anodized aluminum) is stepped; the smallest spot marks the focus. It costs almost nothing, but it measures the effect of the beam, not the beam itself. Thermal effects make spots larger than the real focal spot, the “smallest” spot is picked by eye, and because of the slow change within the beam waist the steps must be about 0.5-1× the Rayleigh length - in practice 0.5-1.5 mm or more. That step is the accuracy limit.

2. Direct beam measurement with a camera system

Optical setups with cameras, filters and beam absorbers measure the beam diameter directly at several to a dozen or more positions along the axis and fit the results to the theoretical beam waist. Accuracy is better than 10 µm - but the systems cost tens of thousands of euros, need free space in the machine and are installed permanently, so every machine needs its own unit.

3. FocusFinder - calculated, not judged

FocusFinder, developed at RMA, sits between the two. The laser engraves a dedicated line pattern on a selected material at multiple focal offsets; the plate is digitized with a high-resolution scanner; software fits the measured line widths to an ideal Gaussian beam curve - the same principle as direct measurement - and returns the position of the minimum effective beam diameter automatically.

FocusFinder engraved test plate being digitized for numerical analysis
FocusFinder workflow: the engraved pattern is digitized and analyzed numerically - no visual judgment by the operator.

The result: 50-100 µm accuracy (down to 50 µm depending on the laser and head optics), no operator subjectivity, and one set that can serve several machines.

Method comparison

Pulse test on plateRMA FocusFinderDirect beam measurement (camera)
What is measuredEffect on materialEffect on material, evaluated numericallyThe beam itself
Focal-position accuracy0.5-1.5 mm or more50-100 µmbetter than 10 µm
ResultVisual, subjectiveAutomatic Gaussian fitAutomatic Gaussian fit
InstallationNoneNone - portablePermanent, needs space in the machine
Machines per unit-SeveralOne
Implementation costA few eurosModerateTens of thousands of euros per machine
Sufficient for 250-300 µm battery jointsNoYesYes
Focal-position accuracy by methodLog-scale comparison: direct beam measurement better than 10 µm, FocusFinder 50-100 µm, pulse test 0.5-1.5 mm or more. Required range for 250-300 µm battery joints: 50-150 µm; above 0.5 mm too coarse.Needed for battery jointsToo coarse > 0.5 mmDirect beam measurementcamera · one per machine< 10 µmRMA FocusFinderone set · many machines50-100 µmPulse test on platevisual assessment0.5-1.5 mm +1 µm10 µm100 µm1 mmFocal-position accuracy · log scale · smaller is better
Accuracy of focal-position determination by method (ranges from the RMA article above). Yellow band: accuracy needed for 250-300 µm Cu/Al battery joints with a ~50 µm spot.

Which method for battery welding?

The two extremes do not fit a battery production floor well: the pulse test is cheap but an order of magnitude too coarse, and camera systems are precise but expensive and tied to a single machine. FocusFinder delivers the accuracy that 250-300 µm joints actually need, removes subjective judgment, and - because one set serves several machines - keeps implementation and operating costs rational.

FocusFinder test plate with engraved line patterns at different focal offsets
FocusFinder test plate: line patterns engraved at different focal offsets, ready for scanning and numerical evaluation.

In RMA machines, focus measurement is one step in the same chain as power verification, part positioning and online weld monitoring - see process control. Details, specifications and demo requests for the instrument: focusfinder.pro and the focusfinder.pro product page.

Need a stable process window on your own cells? We test, validate and optimize laser welding on your materials in the Laser Application Center.

DOWNLOADS

FAQ

How accurately must the laser focal point be determined for battery welding?

For thin battery joints - copper, aluminum and steel in the 250-300 µm range, welded with a focal spot of about 50 µm - the focal position should be determined to within 50-100 µm. Choose a method with a precision of at least 100-150 µm; methods with a precision worse than 500 µm are generally too coarse for these material thicknesses.

Why is the focal point of a single-mode laser hard to find?

The beam is not a physical object, industrial lasers work at about 1,060 nm (invisible infrared), the focal spot is only 45-60 µm in diameter, and near the focus the beam forms a waist whose diameter changes very slowly along the axis (Rayleigh length). Together this makes the point of minimum diameter almost impossible to judge by eye.

What is the difference between the pulse test and FocusFinder?

Both mark a plate at several focal offsets. In the pulse test an operator visually picks the smallest spot, which limits accuracy to roughly 0.5-1.5 mm. FocusFinder engraves a dedicated line pattern, digitizes it with a high-resolution scanner and fits the results to an ideal Gaussian beam curve, so the focal position is calculated - not judged - with an accuracy of 50-100 µm.

Can one FocusFinder be used on several laser machines?

Yes. Unlike camera-based beam measurement systems, which are installed permanently in one machine, FocusFinder is not tied to a machine - one set can serve several welding stations, which lowers implementation and operating costs.

Battery Welder Spot

AVAILABLE FROM STOCK

Battery Welder Spot - available now

A Battery Welder Spot is in stock and ready to ship. Contact us for details.

sales@myrma.eu

BROCHURE 2026 - PDF

Download the brochure

Enter your email and the download starts right away.

This form is protected by reCAPTCHA - Google's Privacy Policy and Terms of Service apply.