Aluminum is increasingly common in cell and module construction. It’s light and conductive - but its behavior under a laser makes stable, repeatable welding a real engineering challenge.
The problem
Aluminum’s oxide layer, high conductivity and crack sensitivity make the process window narrow. Small deviations in energy or focus lead to porosity, cracks and inconsistent penetration - a stability problem across many joints, not just a one-off defect.
How RMA solves it
RMA validates the welding window on your actual parts - metallography, tensile testing - then holds it in production. Focal position is set and verified, energy is controlled per joint, and online monitoring flags deviations as they happen. Stability isn’t assumed; it’s measured.
Technical Parameters
- Documented process windows for battery tab-to-busbar joints: single-beam ~775 W-1 kW at 30 mm/s; dual-beam configurations 1000-1400 W at up to 80 mm/s; dual-mode (core/ring) systems welding at speeds up to 1 m/s. Peer-reviewed
- Beam wobbling controls intermetallic (IMC) formation: wobble amplitude 0.6-0.8 mm at 75-100 mm/s suppressed crack-prone intermetallics in Al/steel busbar joints; optimized welds survived 1 million fatigue cycles at 175 N. Peer-reviewed
- Dual-mode (core/ring) welding: a 40% core / 60% ring power split minimized brittle Al-Cu intermetallic phases while maintaining joint strength. Peer-reviewed
Recommended solutions
Off-the-shelf - Battery Welder
Configured for aluminum joining, with process control that holds the window across many joints. Validate at the LAC, scale across the series.
Explore platform →Custom - Custom Battery Laser Production Lines
For dissimilar-metal (Al-Cu) or high-volume aluminum assemblies, RMA designs a custom machine or line around the application.
Explore platform →Where this fits.
APPLICATION NOTES
Frequently asked questions
Can you weld aluminum to copper?
Yes - dissimilar-metal (Al-Cu) joints are a core capability; the window is validated at the LAC.
How do you prove stability?
Metallographic examination, tensile testing and per-joint monitoring - documented and repeatable.
Do you validate on our cells?
Yes - validation runs on your actual parts before tooling is committed.